Care and Maintenance
7.8.16 Injection valves
Injection valves must be checked by your service
specialist.
7.8.17 Electrical equipment
7.8.17.1 Batteries
The two batteries are located in the rear-end below
the engine hood, behind the left-hand wheelhouse.
Attention
The instructions of the battery manufacturer
must be observed when using the battery for
the first time.
Only check the batteries with the engine switched
off.
The acid level should be approx. 10 mm above the
plates.
If necessary, top up with pure distilled water.
Attention
In the case of maintenance-free batteries,
this check is not necessary.