7.8.17.2 Removing the battery
•
Turn off the battery main switch (78/1).
•
First disconnect the ground cable (79/1) on battery
1 (79/6), then the positive cable (79/2) on battery 2
(79/6).
•
Remove the jump cable (79/3).
•
Release the clamping brackets (79/4; 2 on each
battery side).
•
Lift out the batteries.
7.8.17.3 Installing the battery
•
Place both batteries into the machine.
•
Attach the batteries using 2 clamping brackets for
each battery (79/4).
•
Re-attach the jumper cable (79/3): Connect the
positive terminal (+) of battery 1 (79/5) with the
negative terminal (-) of battery 2 (79/6).
•
Connect the positive cable (79/2) to the positive
terminal (+) of battery 2 (79/6).
•
Connect the ground cable (79/1) to the negative
terminal (-) of battery 1 (79/5).
Machine damage
due to incorrect connection of terminals.
• Ensure that the negative terminal is
connected to the negative pole (–) and the
positive terminal to the positive pole (+).
Attention
In winter, in particular, the battery charge
should be closely monitored.
7.8.17.4 Checking the lighting and warning
equipment
•
Check the function of the lighting equipment.
•
Check the function of the indicator lamps.
•
Check the function of the warning equipment.
TL160
Care and Maintenance
Fig. 78 Battery main switch
6
4
Fig. 79 Removing and installing the battery
Operating Manual 12.9.08 Version 1.0
1
2
5
7
3
1
101/112