7.8.17.2 Removing the battery
Turn off the battery main switch (78/1).
First disconnect the ground cable (79/1) on battery
1 (79/6), then the positive cable (79/2) on battery 2
(79/6).
Remove the jump cable (79/3).
Release the clamping brackets (79/4; 2 on each
battery side).
Lift out the batteries.
7.8.17.3 Installing the battery
Place both batteries into the machine.
Attach the batteries using 2 clamping brackets for
each battery (79/4).
Re-attach the jumper cable (79/3): Connect the
positive terminal (+) of battery 1 (79/5) with the
negative terminal (-) of battery 2 (79/6).
Connect the positive cable (79/2) to the positive
terminal (+) of battery 2 (79/6).
Connect the ground cable (79/1) to the negative
terminal (-) of battery 1 (79/5).
Machine damage
due to incorrect connection of terminals.
• Ensure that the negative terminal is
connected to the negative pole (–) and the
positive terminal to the positive pole (+).
Attention
In winter, in particular, the battery charge
should be closely monitored.
7.8.17.4 Checking the lighting and warning
equipment
Check the function of the lighting equipment.
Check the function of the indicator lamps.
Check the function of the warning equipment.