Electrical System

The power trim pump's electrical system is protected by either a 1A in-line
fuse (Figure 2-9, 1) or an auto-reset circuit breaker (Figure 2-9, 2) located
within the trim motor. In the event of an electrical overload, the fuse will
blow out or the circuit breaker will shut off. Correct the cause of the electrical
overload before operating the trim system. If the electrical overload problem
still exists, consult your authorized Ilmor Marine dealer or distributor.
1

Ilmor Cathodic Protection System

The Ilmor Cathodic Protection System (I-CaPS) has a 20 A in-line fuse
(Figure 2-10) in the wire which connects to the positive (+) terminal on
the controller. If the fuse blows, the system will not operate resulting in a
loss of corrosion protection.
Test I-CaPS to ensure adequate output. The test should be performed
where the vessel is moored, using a reference electrode and test meter.
Consult your authorized Ilmor Marine dealer or distributor for assistance,
if necessary.
© 6/2016 Ilmor Marine Engines, Version 1.0
2
Figure 2-9
I-CaPS controller
Electrode
Figure 2-10
PRODUCT OVERVIEW
20 A in-line
fuse holder
2-11