IP Installer

The IP Installer is an external Windows-based utility for assigning IP addresses
to the RCM KVM over IP Switch. Click one of the radio buttons to select
Enabled, View Only, or Disabled for the IP Installer utility. See p. 141 for IP
Installer details.
Note: 1. If you select View Only, you will be able to see the RCM KVM over
IP Switch in the IP Installer's Device List, but you will not be able to
change the IP address.
2. For security, we strongly recommend that you set this to View Only
or Disabled after using it.

Service Ports

Specify the ports that the RCM KVM over IP Switch uses for various network
services.
 Program: This is the port number for connecting to the RCM KVM over
IP Switch from the Windows Client and Java Viewers, and from the
Windows and Java Client AP programs. The default is 9000.
 HTTP: The port number for a browser login. The default is 80.
 HTTPS: The port number for a secure browser login. The default is 443.
 SSH: The port number for a secure shell login. The default is 22.
 Telnet: The port number for a secure console login. The default is 23.
Note: 1. Valid entries for all of the Service Ports are from 1–65535.
2. The service ports cannot have the same value. You must set a
different value for each one.
3. If there is no firewall (on an intranet, for example), it does not matter
what these numbers are set to, since they have no effect.
If a firewall is being used, the Administrator can specify the port numbers that
the firewall will allow (and set the firewall accordingly). If a port other than the
default is set, users must specify the port number as part of the IP address when
they log in. If not, an invalid port number (or no port number) is specified, the
RCM KVM over IP Switch will not be found.