Package Contents

1 KVM cable(SPHD to VGA, PS/2, USB)
1 USB cable (USB Type-A to Mini-B)
1 control terminal block
1 power adapter
1 mounting kit
1 foot pad set (4 pcs)
1 user instructions

Hardware Overview

Hardware Overview - Front View
Front View

  1. KVM SPHD port
  2. KVM audio ports
  3. CPU COM (RS-232 DTE) port
  4. local console COM (RS-232 DCE) port
  5. laptop USB console (LUC) port
  6. reset button
  7. power LED

Hardware Overview - Rear View
Rear View

  1. grounding terminal
  2. power jacks
  3. control terminal
  4. LAN ports
  5. local console ports

Hardware Overview - Side View
Side View

  1. control port (reserved)

Placement

The unit can be placed on a fl at surface or mounted onto a rack or a wall. If you plan to have your unit mounted onto a rack or a wall, refer to the Placement section of the user manual.

Installation

Installation - Part 1
Installation - Part 2

  1. Connect the unit's grounding terminal to a suitable grounded object. Note: Do not omit this step. Proper grounding helps prevent damage from power surges and static electricity.
  2. Plug your USB keyboard, mouse, and VGA monitor into the local console ports on the rear of the unit.
  3. Using the KVM cable provided, connect the unit's KVM SPHD port to the server/ PC for keyboard, mouse, and video transmissions. Note: For keyboard and mouse signal transmission, you can choose between PS/2 or USB connections.
  4. (Optional) Using self-supplied audio (microphone & speaker) cables, connect the unit's KVM audio ports to the server/PC for audio signal transmission.
  5. (Optional) If you wish to access locally using the laptop USB console (LUC) function, use the USB Type-A to Mini-B cable provided to connect a USB port of the laptop to this LUC port.
  6. (Optional) If you are using serial devices (data terminal equipment), such as a touch panel, connect it to the local console COM (RS-232 DCE) port with a network switch console cable.
  7. (Optional) If you are using serial devices (data communication equipment), such as a PC, connect it to the CPU COM (RS-232 DTE) port with a serial RS-232 DB-9 to RJ-45 Cat5 Ethernet adapter network modem/switch/router cable.
  8. Plug a network cable into one of the unit's LAN Ports.
  9. (Optional) Plug a second network cable into the other LAN port for dual LAN operation.
  10. (Optional) For remote boot operation, connect the NC and C terminals to the server/PC.
  11. (Optional) For digital input notifi cations, connect the GND and DI to an input device (e.g. thermometer, humidity sensor).
  12. Supply power to the unit, thereby turning it on, by plugging the power adapter provided into an AC power source, and plug its cable into one of the unit's power jacks.
  13. (Optional) Connect the unit to another AC power source using a separate, additional power adapter for power redundancy.
    Note: A second power adapter can be purchased from your ATEN supplier.

Operation

  1. Open your browser and specify the IP address of the CN9000 you want to access in the browser's URL location bar. Note: You can get the IP address from the CN9000 administrator, or see the "IP Address Determination" section of the user manual. (Default IP Address: 192.168.0.60)
  2. If a Security Alert dialog box appears, accept the certifi cate — it can be trusted. The Login page appears.
  3. Provide a valid username and password.
    Note: For fi rst-time login, use the default Username and Password: administrator and password.
  4. Click Login to bring up the browser main page.

Local IP Setup

Use the local console to set the IP address. All procedures start from the OSD main screen.

  1. To display the main screen, tap [Scroll Lock] twice.
  2. When the login screen appears, enter a valid username and password.
    Note: For fi rst-time login, use the default Username and Password: administrator and password.

IP Installer

Using a Windows PC within the same LAN, users can search for the unit's IP address or assign an IP address to it with the IP Installer utility. The utility can be obtained from our website www.aten.com. After downloading the utility to the PC, go to the directory that the IP Installer program resides in, and run IPInstaller.exe.

Support and Documentation Notice

All information, documentation, fi rmware, software utilities, and specifi cations contained in this package are subject to change without prior notifi cation by the manufacturer.
To reduce the environmental impact of our products, ATEN documentation and software can be found online at http://www.aten.com/download/

Technical Support www.aten.com/support

Scan for more information

ATEN Website

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download ATEN CN9000 - 1-Local / Remote Share Access Single Port VGA KVM Over IP Switch Quick Start

Advertisement

Need Assistance?

Do you have a question about the CN9000 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents