Pro Spot i5 Instruction Manual page 28

Resistance spot welder
Table of Contents

Advertisement

i5
4.2.3 i5 Touch Screen Control
2. Choose Your Settings
Set the desired parameters by selecting each one to be edited and
modify using the keypad that opens.
Weld
Time (1)
Amount of time applied to the
Weld
Time (2)
Amount of time applied to the
Pulse On
Time
Amount of time each pulse
Pulse Off
Delay
Amount of time between
All Info Copyright © Pro Spot International Inc.
28
If you selected "Single Weld" you are presented
Weld
Time
Amount of time current is applied
If you selected "Double Weld" you are presented
Current (1)
How much current is applied to
first pulse.
Current (2)
How much current is applied to
second pulse.
is applied.
Number of pulses that are applied
each pulse.
4 - Operation
during the weld.
Weld
the first pulse.
Weld
the second pulse.
If you selected "Pulse Weld" you are presented
Weld
Current
How much current is applied
during each pulse.
Pulse
Count
(between 3 and 9)
with these options.
Weld
Current
How much current is applied
during the weld.
Weld
Force
How much pressure is applied
during the weld.
with these options.
Weld
Force
How much pressure is applied
to the weld.
with these options.
Weld
Force
How much pressure is applied
during the weld.