4.2.3 i5 Touch Screen Control
3. Save New Weld Program
Press the green check mark soft key to
accept the changes and return to the Main
Semi-Auto Screen. Finally press the disk
icon to save the newly created stack. An
overwrite message will appear, prompting
you to select "yes" to continue saving or
"no" to cancel.
Welding / On-Screen Feedback:
Place the weld gun in the desired position and press the trigger to
weld.
After a weld is made the weld status screen will show. If the weld was performed
correctly then you will be returned to the Auto Weld screen automatically. If there
was a problem with the weld, the status screen will display what went wrong.
Press the red X button to continue.
IMPORTANT! Turn the power off before disconnecting water hoses from the weld gun.
IMPORTANT! Make sure the water cooling hoses are securely clipped into place before welding.
!
IMPORTANT! The i5 welder comes without coolant to ease transportation, be sure to fill coolant tank before
turning on the welder!
IMPORTANT! If the thermal breaker has switched off the welder, please contact Pro Spot's authorized service personnel
IMPORTANT! N'éteignez pas le soudeur pendant que le système de refroidissement est activé!
IMPORTANT! Si le disjoncteur thermique a éteint le soudeur, s'il vousplaît contactez personnel de service autorisé Pro Spot.