Changing The Settings; Configuration -Config Mode - Sokkia CX Series Operator's Manual

Compact x-ellence station
Table of Contents

Advertisement

33. CHANGING THE SETTINGS

This section explains the contents of parameter settings, how to change settings
and how to perform initialization. Each item can be changed to meet your
measurement requirements.

33.1 Configuration -Config Mode-

The following explains the Config Mode.
Config
Obs.condition
Instr.config
Instr.const
Comms setup
Unit
Observation Condition
Select "Obs. condition" in Config mode
D i s t m o d e
H D i s t
Ti l t c r n
c o l l . c r n
C & R c r n .
S e a l e v e l c r n
V m a n u a l :
Items set and options (*: Factory setting)
Dist mode
H Dist (Horizontal distance
display method)
Tilt crn (Tilt angle
compensation)
coll. crn (Collimation
correction)
C&R crn. (Earth curvature and
refraction correction)
Sea level crn
(Sea level correction)
:
S d i s t
: G r o u n d
: N o
: Ye s
: K = 0 . 2 0
: Ye s
N o
Sdist*, Hdist, Vdist
Ground*, Grid
Yes(H,V)*, Yes(V), No
Yes*, No
No, K=0.142, K=0.20*
Yes, No*
Key function
Change Password
Date and time
V. o b s
:
Z e n i t h
C o o r d .
: N - E - Z
A n g . r e s o
: 1
S h e e t m o d
: O n
O f s V a n g
: H o l d
S t n . I D I n c r.
: 1 0 0
239