Sokkia CX Series Operator's Manual page 284

Compact x-ellence station
Table of Contents

Advertisement

35. CHECKS AND ADJUSTMENTS
3. Note the current position (x) of the
laser beam.
4. Turn the upper part of the
instrument horizontally through
180° and note the new position (y)
of the laser beam.
Adjustment will bring the laser
beam to a point midway along a
line drawn between these two
positions.
5. Check the position of the desired
final position. Place a target so
that its center is aligned with the
desired final position.
The remaining deviation will be
adjusted using the 4 fine
adjustment screws.
:
• Be extremely careful to adjust all
the fine adjustment screws by
the same amount so that none
will be over-tightened.
• Turn screws clockwise to
tighten.
6. When the laser beam is on the
upper (lower) part of Fig. A the up/
down adjustment is made as
follows:
Insert the provided
hexagon key wrench into
both the upper and lower
screws.
274
x
Desired final position
Fine adjustment screws
Target
Desired final position
Fig. A
y