26. CROSS SECTION SURVEY
6. Press [REC]. Enter point name, target
height, and code, then press [OK].
7. Repeat steps 5 to 6 for all points on
the cross-section in the set
observation direction until the
centerline is reached.
8. Observe the center point. Then press
[OK].
Enter center point name. Then press
[OK].
• When the center point is set as the
instrument station, press [LOAD] to
read in already registered coordinate
data and set as the coordinates of
the instrument station.
"13.1 Entering Instrument
Station Data and Azimuth Angle
PROCEDURE Reading in
Registered Coordinate Data
9. Repeat steps 5 to 6 for all points on
the cross-section occuring after the
centerline.
192
1 0 3 . 5 1 4
N
1 0 1 . 4 2 3
E
1 2 . 1 5 2
Z
ZA
HA-R
REC
HT
MEAS
HR
CD
1 5 0 . 5 1 4
N
2 2 0 . 4 2 3
E
8 0 . 1 5 0
Z
REC
HT
MEAS
3 + 3 . 2 0 0
C e n t e r :
N o . 3 + 3 . 2 0 0
F i n i s h e d s e c t i o n :
LOAD
P1
OK
OK
P1
OK
N o
OK