Endress+Hauser Mycom S CLM 153 Operating Instructions Manual page 108

Conductivity transmitter
Table of Contents

Advertisement

11 Appendix
PARAM
Select
Select
Data logger
Data logger
Measuring interval
Data logger 1 /
Data logger 2
PCS time
PCS K1
off
Check
Rec.polaris.K1 off
PCS K2
off
Rec.polaris.K2 off
Activating Controller
function
(contr. must have been
Controller
configured)
configuration
off
on
Select for
configuration:
Limit functions
Limit value sensor 1
...
Limit value sensor 5
Chemoclean
(only with
connected system,
see below)
108
PARAM
Set up 1
Set up 2
Controller values
Manual operation
Quick Setup
Enter
measuring interval
Back to
return field
00005s
(2 ... 36000s)
Data logger1/2
Back to
Meas.value PV K1
return field
Function
off
Back to
return field
Configuration of
Selection process
type:
external hardware:
batch 1-sided up
batch 1-sided down
Type
batch 2-sided
inline 1-sided up
inline 1-sided down
Sensors
Feedback
(Menu option
is hardware
dependent)
Characteristic
Configuration
Configuration
LC 1/2/3/4/5
LC 1/2/3/4/5:
Function: off
Switch-on delay: 0 s
Assignm.:
PV K1
Switch-off delay: 0 s
Switch-on pt.: 1000mS
Alarm
Switch-off pt.: 1000mS
threshold: 1000mS
Control using
Pulse length
single
Pulse frequency
batch/inline
3-point step contr.
Current output
Selection Control
(when relays and
current output defined)
dual
2 outputs
batch/inline
(=2 relays)
1 output
(= current output2)
Flowmeter
Electrodes/dosing
Mycom connection
point intervals
Current output 2
LVB: 0,5 m
LVS: 0,5 m
0 ... 20 mA
LVE: 1,5 m
4 ... 20 mA
With resistance
With resistance
input:
input:
Select range
0 ... 1 kW
Move valve to
0 ... 10 kW
y=0 % and enter
current resistance
Select characteristic
With linear:
type:
Set point
Start neutral zone
linear
End neutral zone
segmented
Kr 1
Kr 2 (only 2-sided)
Back to
return field
Mycom S CLM 153
Relay selection
Relay selection
Pulse frequency:
3-point step contr.:
+Relay: Rel. 1
Relay: n.c.
–Relay: Rel. 2
Max. pulse
Motor running time
XSD
00.00%
frequency
Control
Up/down dosing
Relay selection
3-point step controller:
Down: Impulse length
+Relay: Rel. 1
Up: Impulse length
–Relay: Rel. 2
Motor running time
Position feedback on
Dosing via
Current output 2:
Current output 2:
Assign
100% dosing
0 ... 20 mA
4 ... 20 mA
0/4 mA
20 mA
Flowmeter
Disturbance
volume flow
feedforward
Unit
Function
on
0 mA value: xxx
Limit
050.0
20 mA value: xxx
Kdist.=1:
050.0
Unit
Kmax:
1.7
Nominal diameter: 1/12
Kdisconnect:
1.0
With resistance
With current input:
input:
Select range
Move valve to
y=100 % and
yR=0 ... 100 %
4 ... 20 mA
enter current
20 ... 4 mA
resistance
With segmented:
Process speed
(only linear)
Set point
Slow
Start neutral zone
Standard
End neutral zone
Optimisation point 1/2
Fast
Control point 1/2
User
»Return field«:
press the PARAM
= Code entry required
key to return to
the highlighted
fields.
Endress+Hauser
Relay selection
Pulse length:
Relay: n.c.
Period: 010.0s
tE min: 000.4s
Up/down dosing
Relay selection
Impulsfrequenz:
Relay: n.c.
Max. pulse frequency
Back to
return field
Back to
return field
With current input:
Move valve to
y=0 % and
enter current
resistance
Parameter:
Kr1: 1000mS (only lin.)
Kr2: 1000mS (only lin.)
Tn1:
000.0
Tn2:
000.0
Tv1:
000.0
Tv2:
000.0