Levelflex M FMP43 with FOUNDATION Fieldbus
Tolerance of probe length
Weight
Material
Process connection
Probe
!
Endress+Hauser
10.1.6
Mechanical construction
Tolerance
+ 0 / - 3 mm
+ 0 / - 5 mm
1000 to < 4000 mm
Part
Weight
T12 housing
approx. 2.7 kg
F12 housing
approx. 1.8 kg
F23 housing
approx. 5 kg
Compact probe
approx. 0.7 kg
Compact probe, removable
approx. 0.8 kg
Separate probe
approx. 2.1 kg
Probe rod
approx. 0.4 kg/
m
• Housing:
– housing F12/T12: aluminum (AlSi10Mg), seawater-resistant, powder-coated
– housing F23: 316L, corrosion-resistant steel
• Sight window: glass
See "Ordering structure" on → ä 8.
See "Ordering structure" on → ä 8.
Note!
The modular structure of the probe makes a simple possible exchanges of the process seals, the
probe rod and the process coupling ring.
Rod length
< 1000 mm
Technical data