Endress+Hauser Fieldbus Levelflex M FMP43 Operating Instructions Manual page 42

Guided level-radar
Hide thumbs Also See for Fieldbus Levelflex M FMP43:
Table of Contents

Advertisement

Operation
42
Example: Start-up using the NI-Fieldbus configurator
Start the bus configuration tool. After start-up, the tool shows the network configuration in the form
of an expandable tree. If the Levelflex M has been connected correctly, it can now be identified:
E+H_LEVELFLEX_M_XXXXXXXX
A double click on the name reveals the device data:
PD_TAG the physical name of the device
DEVICE_ID the unique device identifier
NODE_ADDRESS the fieldbus node to which the device is connected (is automatically allocated by the
Configurator)
The device ID is made up of the following components:
Device_ID = 452B481012-XXXXXXXX
whereby:
452B48 ID code for Endress+Hauser
1012 ID code for Levelflex M
XXXXXXXX Device serial number, as printed on the nameplate
A right-hand mouse click on the name opens up a menu from which the PD_TAG and
NODE_ADDRESS can be changed
A click on the name expands the device tree to show the function blocks available for it:
E+H_LEVELFLEX_M_XXXXXXXX
Levelflex M FMP43 with FOUNDATION Fieldbus
RESOURCE_XXXXXX (RB2)
SENSOR_XXXXXX (TBGRL)
DIAGNOSTIC_BLOCK_XXXXXX (DIAG)
DISPLAY_BLOCK-XXXXXX (DISP)
ANALOG_INPUT_1_XXXXXX (AI)
ANALOG_INPUT_2_XXXXXX (AI)
PID_XXXXXX(PID)
AR_XXXXXX (AR)
IS_XXXXXX (IS)
SC_XXXXXX (SC)
IT_XXXXXX (IT)