Operation
Parameter
Position
Indicator
measured value
000
tank properties
002
medium property
003
process propert.
004
end of probe
030
probe length
031
probe
032
probe length
033
determine length
034
empty calibr.
005
full calibr.
006
echo quality
056
check distance
051
range of mapping
052
start mapping
053
pres. map dist.
054
delete mapping
055
offset
057
output damping
058
upper block.dist
059
output on alarm
010
outp. echo loss
012
ramp %span/min
013
delay time
014
safety distance
015
in safety dist.
016
ackn. alarm
017
broken probe det
019
level/ullage
040
linearisation
041
customer unit
042
table no.
043
input level
044
input level
044
input volume
045
max. scale
046
diameter vessel
047
simulation
065
46
Most of these methods are identical to the respective function group in the operating menu. A
detailed description of them can be found in the "Description of Instrument functions", BA245F/
00/en.
Parameter list of the Levelflex M Sensor Block
rel.
Variable Name
Index
18
PARMEASUREDVALUE
19
PARTANKPROPERTIES
20
PARMEDIUMCONDITION
21
PARPROCESSPROPERTIES
22
PARENDOFPROBE
23
PARPROBESHORTEND
24
PARPROBEFREE
25
PARPROBELENGTH
26
PARPROBELENGTHSETUP
27
PAREMPTYCALIBRATION
28
PARFULLCALIBRATION
29
PARECHOQUALITY
30
PARCHECKDISTANCE
31
PARSUPPRESSIONDISTANCE
32
PARSTARTMAPPINGRECORD
33
PARPRESMAPRANGE
34
PARDELETEMAPPING
35
PAROFFSETOFMEASUREDDISTANCE
36
PAROUTPUTDAMPING
37
PARHIGHBLOCKINGDISTANCE
38
PAROUTPUTONALARM
39
PARREACTIONLOSTECHO
40
PARRAMPINPERCENTPERMIN
41
PARDELAYTIMEONLOSTECHO
42
PARLEVELWITHINSAFETYDISTANCE
43
PARINSAFETYDISTANCE
44
PARACKNOWLEDGEALARM
45
PARBROKENPROBEDETECTION
46
PARLEVELULLAGEMODE
47
PARLINEARISATION
48
PARCUSTOMERUNIT
49
PARTABLENUMBER
50
PARINPUTLEVELHALFAUTOMATIC
51
PARINPUTLEVELMANUAL
52
PARINPUTVOLUME
53
PARMAXVOLUME
54
PARCYLINDERVESSEL
55
PARSIMULATION
Levelflex M FMP43 with FOUNDATION Fieldbus
Size
Type
Access Storage
[bytes]
4
FloatingPoint
RO
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
4
FloatingPoint
RW
1
Unsigned8
RW
4
FloatingPoint
RW
4
FloatingPoint
RW
2
Integer16
RO
1
Unsigned8
RW
4
FloatingPoint
RW
1
Unsigned8
RW
4
FloatingPoint
RO
1
Unsigned8
RW
4
FloatingPoint
RW
4
FloatingPoint
RW
4
FloatingPoint
RW
1
Unsigned8
RW
1
Unsigned8
RW
4
FloatingPoint
RW
2
Unsigned16
RW
4
FloatingPoint
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
1
Unsigned8
RW
2
Unsigned16
RW
1
Unsigned8
RW
4
FloatingPoint
RO
4
FloatingPoint
RW
4
FloatingPoint
RW
4
FloatingPoint
RW
4
FloatingPoint
RW
1
Unsigned8
RW
Changeable
Class
in Mode
dynamic
Auto, OOS
static
OOS
static
OOS
static
OOS
static
OOS
dynamic
OOS
dynamic
OOS
static
OOS
dynamic
OOS
static
OOS
static
OOS
dynamic
Auto, OOS
dynamic
OOS
dynamic
OOS
dynamic
OOS
dynamic
Auto, OOS
dynamic
OOS
static
OOS
static
Auto, OOS
static
OOS
static
OOS
static
OOS
static
OOS
static
OOS
static
OOS
static
OOS
dynamic
Auto, OOS
static
OOS
static
OOS
static
OOS
static
OOS
non-vol.
Auto, OOS
dynamic
Auto, OOS
dynamic
OOS
dynamic
OOS
static
OOS
static
OOS
dynamic
OOS