Guided level-radar
Hide thumbs Also See for Fieldbus Levelflex M FMP43:
Table of Contents

Advertisement

Levelflex M FMP43 with FOUNDATION Fieldbus
KA189F/00/a2/03.07
52012501
000
Contrast:
measured value
-
+
E
Group
selection
00
002
basic setup
tank
properties
+
01
- standard
safety settings
- aluminium tank
- plastic tank
- bypass/pipe
- coax-probe
- concrete
wall
03
030
length
end of
adjustment
probe
- free
04
- tie down
linearisation
isolated
- tie down
05
extended calibr.
gnd.
092
09
language
display
0E
09A
envelope curve
plot settings
- envel. curve
- substracted signal
- mapping
-
0A0
0A
present
diagnostics
error
0C
system
parameters
!
Endress+Hauser
Brief operating instructions
Levelflex M - Brief operating instructions
+
or
+
-
+
003
004
005
process
empty
medium
property
cond.
calibr.
- unknown
- standard
input E
- 1.4 ... 1.6
- fast
(see sketch)
- 1.6 ... 1.9
change
- 1.9 ... 2.5
- slow
- 2.5 ... 4
change
- 4 ... 7
- test: no filter
- > 7
031
032
033
probe
probe
probe
length
length
If shortened
please enter probe length here.
... ...
09B
recording
curve
- single curve
- cyclic
0A1
0A3
previous
reset
error
(333 = reset customer parameters)
Note!
These Operating Instructions explain how to install and commission the level transmitter. All the
functions that are required for a typical measuring task are taken into account here.
In addition, the Levelflex M has many other functions that are not included in these Operating
Instructions, such as functions for optimizing the measuring point and converting the measured
value.
An overview of all the device functions can be found on → ä 100.
An extensive description of all the device functions can be found in BA245F – "Description of
Device Functions" on the CD-ROM provided.
Operating Instructions can also be found on our homepage: www.endress.com
E
E
006
008
051
check
full
dist./
calibr.
meas value
distance
input F
D and L are
(see sketch) displayed
FMP43
034
determine
length
threaded
connection
¾ or
1 ½
BSP
(G
¾ or G ½)
1
¾ or 1½ NPT
:
reference point of
measurement
UB = upper blocking distance
0A4
E = empty distance (= zero)
... ...
unlock
D = distance
parameter
= 100: unlocked
¹ 100: locked
Brief overview
008
E
dist./
meas value
052
053
start
range of
mapping
mapping
confirm
suggestion
FMP40
or specify
FMP41C
range
FMP45
reference point of
measurement
UB
D
E
LN
F
L
F = measuring span
LN = probe length
L = level
52012501
L00-FMP40xxx-19-00-00-en-012
100%
0%
3

Advertisement

Table of Contents
loading

Table of Contents