Endress+Hauser Fieldbus Levelflex M FMP43 Operating Instructions Manual page 37

Guided level-radar
Hide thumbs Also See for Fieldbus Levelflex M FMP43:
Table of Contents

Advertisement

Levelflex M FMP43 with FOUNDATION Fieldbus
"
ENDRESS + HAUSER
+
E
Endress+Hauser
5.3.3
Factory settings (reset)
Caution!
A reset sets the device back to the factory settings. This can lead to an impairment of the
measurement. Generally, you should perform a basic setup again following a reset.
A reset is only necessary:
• If the device no longer works
• If the device must be moved from one measuring point to another
• If the device is being removed/put into storage/installed
User input ("reset" (0A3)):
• 33333 = customer parameters
33333 = reset customer parameters
This reset is recommended whenever a device with an unknown 'history' is to be used in an
application:
• The Levelflex is reset to the default values.
• A customer-specific tank map is not deleted.
• The mapping can be deleted in the "cust. tank map" (055) function of the "extended
calibr" (05) function group.
• A linearization is switched to "linear" but the table values are retained. The table can be
reactivated in the "linearization" (04) function group.
List of functions that are affected by a reset:
• Tank properties (002)
• Medium property (003)
• Process proper. (004)
• Empty calibr. (005)
• Full calibr. (006)
• Output on alarm (010)
• Outp. echo loss (012)
• Ramp %span/min (013)
• Delay time (014)
• Safety distance (015)
• In safety dist. (016)
• Overfill protection (018)
• End of probe (030)
• Level/ullage (040)
• Linearization (041)
• Customer unit (042)
• A complete "basic setup" (00) must be activated.
• Max. scale (046)
• Diameter vessel (047)
• Check distance (051)
• Range of mapping (052)
• Start mapping (053)
• Offset (057)
• Output damping (058)
• Language (092)
• Back to home (093)
• Format display (094)
• No of decimals (095)
• Sep. character (096)
• Unlock parameter (0A4)
• application par (0A8)
• tag no (0C0)
Operation
37

Advertisement

Table of Contents
loading