Manual for ZBL-U5 series of Ultrasonic Detector
object procedure. Object data tested previously will be saved
automatically prior to new object being set up.
Integrity of current object data (whether test points have been
tested or not) will be checked prior to new object operating, if
incomplete, then corresponding prompt information will be displayed.
3.
Row number
Row number refers to total quantity of grid transverse row
arranged on object to be tested, which input range is from 1 to 50.
4.
Column number
Column number refers to total quantity of grid vertical line
arranged on object to be tested, which input range is from 1 to 50.
5.
Test Distance
Test distance refers to the distance of dissemination of acoustic
wave, i.e. the centre-to-centre spacing between transmitting and
receiving transducers, in other words, the distance between two test
surfaces of the object which generally refers to the value of thickness,
which range is 1∼5000mm.
6.2.2

Advanced parameter

Press Advanced button in parameter interface to switch to
corresponding property page (as shown in Figure 6.3), Sampling
interval, Transmit voltage, Zero acoustic time and other parameters
may be set up at this page.
After all parameters being set up, press OK button, then all
setting ups are valid and those setting up values of every parameter
will be written into initialization files and return to basic parameter
setup interface; press Cancel button then all setting ups are invalid and
return to basic parameter setup interface.
Press Reset button in Advanced parameter setup interface to pop
up dialogue box inquiring "Whether restore parameter to factory
92