displayed in the waveform area. At that moment, Sample button will
be changed into Stop button. Exit button became Search button that
will be used for searching head wave.
Note: Detailed information of waveform operating
please see public module waveform operating. If the data needs
to be saved, then new object name must be input prior to
sampling; if the object name fails to be input, the Save button
will become invalid.
1.
Save The First Test Point
After the first test point having been adjusted, press the Save
button, and the current test point data will be saved and the data list
area will display one line of data saved a moment ago.
2.
Test of the Subsequent Test Point
After the first test point having been saved, move the two
transducers down to the next test point, press the Save button upon
properly adjustment of waveform, repeat such process again and again
until the completing of test on all test points.
Note: Under the dynamic sampling status, Stop, Save,
and Search buttons are valid, but other buttons will be set grey
color

5.3.2 Stop sampling

During the sampling process, it may stop sampling by pressing
Stop button, and then Stop button changes to be Sample button, and
Search button becomes Exit button, it will automatically implement
calculation, refresh calculation results and save data automatically into
the disc.