Oblique Test - Novatest ZBL-U5 Series Instruction Manual

Ultrasonic detectors
Table of Contents

Advertisement

Manual for ZBL-U5 series of Ultrasonic Detector

4.3.6 Oblique test

When carry out oblique test for foundation pile after flat test,
press Diagonal button to enter into the interface as shown in Figure
4.11, select the section for oblique test.
1.
Select oblique test section
Press view area in oblique test interface, a cursor line will appear;
use up and down buttons in floating toolbar to adjust the position of
cursor line and move it to proper height, press Upper and Lower to
terminate the defect area. Press Clear button to clear all selected
defect areas. Press Exit button to return to previous interface (static
collection interface, which is the interface before enter into oblique
test).
Note: Selected defect areas must appear in pair and
cannot be overlapped. Move cursor to the middle position of
defect area to change the upper limit or lower limit in this area.