2.Create new object
When move to the next object after the completion of the last,
press the New button behind the Component to clean the data of the
current object and create a new crack test file to conduct the test of the
new object. The tested data will be saved automatically before
creating new object.
3.Starting point spacing
The starting point spacing is the distance between the
transmitting of the first test point and the inner edge of the receiving
transducer, generally 100mm.
4.Step spacing
The relative moving distance of transmitting and receiving
transducer is generally 50mm.

7.2.2 Advanced parameter

Press the Advanced button at the parameter interface to enter
into the advanced parameter interface and set Sampling interval,
Transmitting voltage, Zero acoustic time, etc, as shown in Figure 7.3.
After setting all parameters, press the OK button to validate all
settings, writing the values of parameters into the initialization file and
return to the basic parameter setup interface; press the Cancel button
and the setting gets invalid and return to the basic parameter setup
interface.
Press Reset button at advanced parameter interface to pop up the
dialogue box inquiring "Whether restore parameter to factory
setting?"; press Yes button to restore all parameters to factory setting
and No for not.
Advanced parameters need to be set for only once and it is not
required to set every time.