Dynamic Waveform Operation - Novatest ZBL-U5 Series Instruction Manual

Ultrasonic detectors
Table of Contents

Advertisement

Manual for ZBL-U5 series of Ultrasonic Detector
line will be possibly judged as head wave; the two dotted
lines above and below base line, as shown in Figure 3.4, are
threshold value lines.
7)
Base line: The approximate straight line in front of head
wave in the waveform. Longitudinally symmetrical central
line of single- channel waveform.
8)
Automatic interpretation line for acoustic time: It is used to
indicate the mark line for ultrasonic system to automatically
test and read acoustic time position of head wave.
9)
Automatic interpretation line for amplitude: It is used to
indicate the mark line for ultrasonic system to automatically
test and read the amplitude position of head wave.
10) Gain: The magnification to received signal by the system.
11) Number of delay points: The number of transmission
starting
single-channel waveform range.

3.5.2 Dynamic waveform operation

1) Adjust gain
Press 【+】 and 【-】 button or slide up and down on waveform
range to increase or decrease gain.
2) Move dynamic waveform
Slide the position of central base line of single- channel
waveform forward and backward or press 【 】 or 【 】buttons to
move dynamic waveform left or right, and consequently, decrease or
increase number of delay points;
3) Automatic search
points
relative
31
to
"0"
point
position
in