SERVICE CONNECTIONS

Warning: A licensed electrician must perform all AC electrical service connections
to the printer.
Consult a licensed electrician to comply with all applicable local and national electric
codes.
Do not apply power to the printer until the installation service representative has
verified that AC service connections have been made correctly.
After removing the lower rear panel (see
terminal block as follows
Line 1 connects to terminal block L1 (black out).
Line 2 connects to terminal block L2 (red out).
Line 3 connects to terminal block L3 (blue out).
N is neutral (white out).
Ground wire connects to the ground lug (protective earth).
Electrical
Service
Terminal
Block
Ground Lug
(protective
earth)
Figure
(Figure
15):
Figure 15: Line Connections
*Line connections at lower right corner of printer, as viewed from the rear.
10), connect the printer to the electrical service