Environmental Requirements; Heat Output; Power Consumption; Electrical Requirements - Stratasys Fortus K5 Series Site Preparation Manual

Table of Contents

Advertisement

ENVIRONMENTAL REQUIREMENTS

The 380mc and 450mc are for indoor use only.
Air quality conditions with excessive solid particulates (conductive or
non-conductive) may result in system damage.
Air quality conditions in which airborne oils are allowed to accumulate on or within the printer
can damage the plastic components.
Operating temperature shall be in the range of 65°F to 86°F (18°C to 30°C), with relative
humidity range of 30% to 70% non-condensing.
Storage temperature shall be in the range of -40°F to 129.2°F (-40°C to 54°C), with relative
humidity range of 10% to 85% non-condensing.
Altitude shall not exceed 6561.68 feet (2000 m).
Noise emission (acoustic):
<65dBA when idle
<66dBA when building

HEAT OUTPUT

Heat dissipation occurs mostly through the top of the printer. Heat output is material dependent due to the
various temperatures maintained in the build chamber.
Material Type
ABS
PC
ULTEM 9085 (resin)
ULTEM 1010 (resin)

POWER CONSUMPTION

Power consumption is material dependent due to the various temperatures maintained in the build chamber.
Material Type
ABS
PC
ULTEM 9085 (resin) 4500W
ULTEM 1010 (resin) 5850W

ELECTRICAL REQUIREMENTS

AC POWER REQUIREMENTS

50/60 Hz 5 wire (LLL+N+PE) dedicated circuit.
Voltage: 120/208 VAC 3 phase nominal.
Current: 18A.
In-rush: 50 Amps max for less than 10 milliseconds, 21 Amps max for less than 20 seconds.
Maximum input voltage variation: ±10% of nominal.
Leakage (touch) current: <1.0mA (under all conditions), 0.0mA (when OFF).
Heat Output (while building)
~8,000 BTU/hr
~12,500 BTU/hr
~15,500 BTU/hr
~19,900 BTU/hr
Power Consumption
(while building)
2250W
3550W
Heat Output (while idle)
~7,000 BTU/hr
~11,500 BTU/hr
~14,500 BTU/hr
~18,550 BTU/hr
Power Consumption
(while idle)
2050W
3000W
4200W
5450W