Operation of the printer outside this range is not recommended; degradation of performance and shortened
component life expectancy will be experienced. The printer is to be operated on a 3-phase service meeting the
recommendations for power quality given in IEEE Standard *141-1993. Facilities who are unsure of their power
quality should contact their service provider.
* IEEE Standards licensing rules prohibit Stratasys from distributing the Standard. End users who wish to review the Standard are
responsible for its individual purchase.

OPTIONAL UPS CONNECTIVITY

A connector at the rear of the printer is provided allowing an external UPS to initiate the safe shutdown of the
printer. At a minimum the external UPS should meet the following minimum requirements:
Output power rating:
Output waveform: sine-wave
Run time: UPS must be rated to provide a minimum of 7 minutes of battery operation.
Note: Stratasys does not recommend external UPS makes or models.
Additionally, the cable and connector interfacing the UPS to the printer is the
responsibility of the UPS supplier and/or end user.
About the printer UPS connector:
The UPS connector is located in lower most position of the rear connection plate. See
The printer's connector profile is female D-Sub 9 pin; this is NOT a serial communication port.
Only pins 7 and 9 of the connector are used with remaining pins having no internal connections.
When the circuit between pins 7 and 9 is open (>5000ohms) the printer operates normally.
Closing the circuit (<400ohms) between pins 7 and 9 initiates a safe shutdown process as if the
front power off button was depressed.
Rear Connection Plate

OPTIONAL AC TRANSFORMERS

Two optional AC transformers are available from Stratasys for facilities with AC electrical services outside of the
208 VAC specification. The transformers meet applicable electrical and safety standards and carry both the CE
Mark and the Mark of a Nationally Recognized Test Laboratory (NRTL) for North America.
A transformer electrical wiring diagram, for use by a qualified electrician, is located within the transformer.
Transformer PN
155-01200
155-01400
>
10KVA
Figure 2: UPS Connections
Specifications
8.0 KVA 200-240 VAC 50/60 Hz Delta-Wye
8.0 KVA 380-480 VAC 50/60 Hz Delta-Wye
Simplified UPS Configuration
Weight
195 pounds (88 kg)
200 pounds (90 kg)
5
Figure