FI–12
EFI SYSTEM
–
Inspection Precautions
8.
Care is required when pulling out and inserting wiring
connectors.
(a) Release the lock and pull out the connector, pulling on
the connectors.
(b) Fully insert the connector and check that it is locked.
9.
When inspecting a connector with a volt/ohmmeter.
(a) Carefully take out the water–proofing rubber if it is a
water–proof type connector.
(b) Insert the test probe into the connector from wiring side
when checking the continuity, amperage or voltage.
(c) Do not apply unnecessary force to the terminal.
(d) After checking, install the water–proofing rubber on the
connector securely.
10. Use SST for inspection or test of the injector, cold start
injector or its wiring connector.
SST 09842–30050 (A) and 09842–30070 (B)