Safety; Intended Use; Improper Use - ITT Bornemann SLH-4U Operating Instructions Manual

Screw pump
Table of Contents

Advertisement

Safety

2
Safety

2.1 Intended use

2.2 Improper use

10
n
Use pump exclusively for pumping the agreed pumped medium (
datasheet).
n
Adhere to operating limits (
n
Avoid dry running:
Ensure that the pump is only put into operation with pumped medium and
is not operated without pumped medium (
bleeding' on page 49).
n
Avoid cavitation:
Open the inlet side valve fully during pump operation and do not use for
regulating the pump capacity.
Open the outlet side valve fully during pump operation.
Never operate the pump against a closed or partially closed valve in the
n
outlet line.
n
Avoid motor damage:
Observe permissible number of motor switch-on instances per hour (
manufacturer's instructions).
n
Only use the pump if it is in a technically optimal condition and ensure it is
operated in accordance with the regulations and in a safety and risk-aware
manner in accordance with this manual.
n
Any other use must be agreed with the ITT Bornemann GmbH.
Observe the operational limits of the pump in relation to temperature, pres-
n
sure, viscosity, pump capacity and speed (
n
When pumping liquids containing solids, comply with the limit values for the
proportion of solids and grain size (
When pumping liquids containing gas, comply with the limit values for the gas
n
content (
n
Incorporate suitable safety valves (pressure safety valves are not system
safety valves).
n
Do not use the pump without a pressure safety valve or similar safeguard
against exceeding the differential pressure.
n
Do not use the pressure safety valve for regulating the pump capacity or
pressure.
n
Do not operate the pump without a check valve.
Connect the inlet and outlet lines correctly in accordance with the direction of
n
flow (see connection labelling).
n
Check the installation direction of the check valve.
n
Implement and check the connection labelling for the inlet and outlet lines.
Any use other than uses detailed under
shall be considered improper and is impermissible, for example:
Type SLH-4U
DANGER!
Mortal danger in the event of non-compliance with the docu-
mentation!
Observe all of the documentation relating to the pump and all
system components.
Reading and observing the documentation is a prerequisite for
proper use of the product.
pump data sheet).
pump data sheet).
03/2020 JP Rev. 1
Ä Chapter 6.1.7 'Filling and
pump data sheet).
pump data sheet).
Ä Chapter 2.1 'Intended use' on page 10
pump

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bornemann SLH-4U and is the answer not in the manual?

Questions and answers

Table of Contents