6.2.3 Switching off

6.3 Cleaning/sterilizing the pump

4.
For pumps with hot conveyed medium: Ensure temperature change of less
than 2 K/min.
NOTICE!
Property damage due to voltage peaks!
Only switch the unit off using the EMERGENCY STOP button in
an emergency!
1.
Switch off the motor. Maintain the following functions, if present:
for double mechanical seals: Sealing pressure, until pump is pressure-
n
free (
manufacturer's data)
n
Sealing system
n
Cooling water supply until the pump operating temperature has
dropped below 100 °C.
2.
Close the inlet and outlet side valves.
3.
Close the outlet side valves.
4.
If present and permitted in the process: switch off heating.
n
The conveyed medium must not solidify.
5.
Open the drain screw until the pump is depressurised.
6.
Screw in and tighten the drain screw.
7.
Clean / sterilise the pump, if necessary (
the pump' on page 54).
SLH and SLH-S series pumps can be cleaned/sterilised without dis-
mantling.
Determine CIP medium and CIP temperature in accordance with the
operating requirements.
NOTICE!
Damage to pumps, hoses and fittings with pressure testing or
rinsing!
When carrying out pressure tests or rinsing do not expose
pumps, hoses or fittings to impermissible pressure.
Separate pumps, hoses or fittings from the system in advance,
if necessary.