Prerequisites:
Procedure:
7.4.2 Return pump to the manufacturer
Prerequisites:
NOTICE!
Property damage due to improper transportation!
–
Do not lift the pump by its bearing case or gear case.
–
Ensure that the pump unit is not overly tensioned when it is
lifted.
–
Ensure that the lifting tackle cannot damage pipelines or units
when lifting, possibly use a lifting frame (
ings, operating instructions for pump system).
–
Make personal safety equipment available.
–
Observe statutory or other safety and accident prevention regu-
lations.
n
Pump switched off and safeguarded against being switched on again.
n
Pump pressure-free.
n
Pump completely emptied and rinsed.
n
Pump disconnected from the electrical system.
n
Inlet and outlet-side valves shut and safeguarded against unintentional
opening.
n
Pump cooled.
n
Coupling guard dismantled.
n
For coupling with spacer: Remove spacer.
Remove the pump from the system.
Repair work may only be executed if the declaration of no objection
has been received (
on page 74).
n
Pump removed.
Pump cooled.
n
n
Pump cleaned.
n
All flanges and screw bores plugged.
1.
Only return pump or individual components to ITT Bornemann GmbH with
a completed declaration of no objection (
objection' on page 74).
2.
Depending on the desired repair, observe the required measures for return
in accordance with the following table.
03/2020 JP Rev. 1
Maintenance and repairs
Ä Chapter 9.2 'Declaration of no objection'
Ä Chapter 9.2 'Declaration of no
Type SLH-4U
dimensional draw-
65
Need help?