Fault number
Cause
1 2 3 4 5 6 7
- X - X - - - Temperature of the conveyed medium too high:
Pump cavitating.
- X - X - - X Outlet side valve insufficiently opened.
- - X X - - X Speed too high.
- - - - - X - Pump leaking.
- - - X - - - Coupling elements worn.
Coupling not properly aligned.
- - - X - - - Insufficient oil in gear casing.
- - - X - - - Insufficient oil in bearing casing.
- - - X X - - Pipelines too tight.
- - - X X - X Expansion of the internal pump components under
excessive temperatures.
- - - X X - X Bearings/gears faulty.
- - - X X - X Pump excessively tight.
- - - X X - X Motor bearings faulty.
03/2020 JP Rev. 1
Remedy
n
Lower temperature.
n
Adjust speed.
n
Consult with ITT Bornemann GmbH.
n
Fully open the outlet side valve.
n
Lower speed with speed regulator.
n
Consult with ITT Bornemann GmbH.
n
Check and, if necessary, replace the coupling
elements.
Ä Chapter 5.5 'Aligning the pump assembly'
(
on page 32)
Top up oil.
n
Ä 'Filling lubricating oil' on page 63).
(
n
Top up oil.
(
Ä 'Filling lubricating oil' on page 63).
n
Check pipeline.
n
Connect pipelines so that they are slack.
n
Wait for the temperature to equalise.
n
Consult with ITT Bornemann GmbH.
If necessary, send the pump to ITT Bornemann
GmbH.
n
Check the connections and pipeline nozzles and
fastenings on the pump.
Check the alignment of the coupling.
n
n
Check the fastening of the support.
n
Check foundation.
n
Consult the manufacturer.