B7Xxyyyy Licensed Internal Code Srcs - IBM PS703 Service Manual

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 16. B2xxyyyy Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Reference Code
Description
B200F003
During the startup of a partition, the
partition processor(s) did not start
the firmware within the time-out
window.
B200F004
Informational system log entry only.
B200F005
Informational system log entry only.
B200F006
During the startup of a partition, the
code load operation for the partition
startup timed out.
B200F007
During a shutdown of the partition,
a time-out occurred while trying to
stop a partition.
B200F008
Informational system log entry only.
B200F009
Informational system log entry only.
B200F00A
Informational system log entry only.
B200F00B
Informational system log entry only.
B200F00C
Informational system log entry only.
B200F00D
Informational system log entry only.

B7xxyyyy Licensed internal code SRCs

A B7xxyyyy system reference code (SRC) is an error code or event code that is related to licensed internal
code.
Table 17 describes the system reference codes that might be displayed if system firmware detects a
problem. Suggested actions to correct the problem are also listed.
Note: For problems persisting after completing the suggested actions, see "Checkout procedure" on page
176 and "Solving undetermined problems" on page 223.
Table 17. B7xxyyy Licensed internal code SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
0102
0103
50
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description
System firmware detected an error. A
machine check occurred during startup.
System firmware detected a failure
Action
Collect the partition dump information; then, go to
"Isolating firmware problems" on page 216.
No corrective action is required.
No corrective action is required.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 216.
Check for server firmware updates; then, install the
updates if available.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
Action
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 216.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 216.