Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA210103
BA220010
BA220020
BA278001
BA278002
BA278003
BA278004
BA278005
BA278006
Description
There was a communication failure
between partition firmware and the
hypervisor. There was a failing return
code with the lpevent acknowledgement
from the hypervisor.
There was a partition firmware error
during a USB hotplug probing. USB
hotplug may not work properly on this
partition.
CRQ registration error; partner vslot
may not be valid
Failed to flash firmware: invalid image
file
Flash file is not designed for this
platform
Unable to lock the firmware update lid
manager
An invalid firmware update lid was
requested
Failed to flash a firmware update lid
Unable to unlock the firmware update
lid manager
Action
1. Review the event log for errors that
occurred around the time of this error.
2. Correct any errors that are found and
reboot the blade server.
3. If the problem persists:
a. Reboot the blade server.
b. If the problem persists:
1) Go to "Checkout procedure" on
page 176.
2) Replace the system-board, as
described in "Replacing the FRU
system-board and chassis assembly"
on page 264.
1. Look for EEH-related errors in the event
log.
2. Resolve any EEH event log entries that are
found.
3. Correct any errors that are found and
reboot the blade server.
4. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
Verify that this client virtual slot device has a
valid server virtual slot device in a hosting
partition.
Download a new firmware update image and
retry the update.
Download a new firmware update image and
retry the update.
1. Restart the blade server.
2. Verify that the operating system is
authorized to update the firmware. If the
system is running multiple partitions, verify
that this partition has service authority.
Download a new firmware update image and
retry the update.
Download a new firmware update image and
retry the update.
Restart the blade server.
Chapter 2. Diagnostics