IBM PS703 Service Manual page 165

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2625-701
2625
2625-702
2625
2625-703
2625
2625-704
2625
2625-705
2625
2625-706
2625
2640-121
2640
2640-131
2640
2640-132
2640
2640-133
2640
2640-134
2640
2640-136
2640 2631
268B-102
268B
268B-104
268B
268B-105
268B
Description and Action
Error Log Analysis indicates that this adapter has failed due to an internal error.
Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor. Replace the 2-port
QDR 40 GB/S InfiniBand expansion card (CFFh).
Error Log Analysis indicates that this adapter has failed due to a memory error.
Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error. Replace the 2-port QDR 40 GB/S InfiniBand expansion card
(CFFh).
Error Log Analysis indicates that this adapter has failed due to a internal error. Replace
the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Error Log Analysis indicates that this adapter has failed due to a memory error.
Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Physical volume hardware error. Go to "Performing the checkout procedure" on page
177.
Smart status threshold exceeded. Go to "Performing the checkout procedure" on page
177.
Command timeouts threshold exceeded. Go to "Performing the checkout procedure"
on page 177.
Command timeout with error condition. Go to "Performing the checkout procedure"
on page 177.
Hardware command or DMA failure. Go to "Performing the checkout procedure" on
page 177.
Timeout waiting for controller or drive with no busy status. Go to "Performing the
checkout procedure" on page 177.
An unrecoverable media error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
The motor failed to restart.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
The drive did not become ready.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
153
Chapter 2. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps704

Table of Contents