Table 30. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
ssss-116
ssss
ssss-117
ssss
ssss-118
ssss 252B
ssss-120
ssss
ssss-122
ssss
ssss-124
ssss
ssss-126
ssss 252B
ssss-128
252B ssss
software
Description and action
A protocol error.
1. Make sure that the device, adapter and diagnostic firmware, and the application
software levels are compatible.
2. If you do not find a problem, call your operating-system support person.
A write-protect error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
A SCSD command time-out occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
A SCSD busy or command error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
A SCSD reservation conflict error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
A SCSD check condition error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
A software error was caused by a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
The error log analysis indicates a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 264.
171