IBM PS703 Service Manual page 156

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
950-2506
2506 221
2506-102E
722
2506-3002
722
2506-3010
722
2506-3020
-
2506-3100
-
2506-3109
-
2506-3110
-
2506-4010
-
2506-4020
-
2506-4030
-
2506-4040
-
2506-4041
-
2506-4050
-
2506-4060
-
2506-4100
-
2506-4101
-
2506-4110
-
2506-4150
2506
2506-4160
2506
2506-7001
722
144
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description and Action
Missing options resolution for 3Gb SAS Adapter card.
Try each of the following steps. After reseating, removing, or replacing a part, retry the
operation.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Reseat the 3Gb SAS Adapter card.
4. Replace the 3Gb SAS Adapter card.
5. Replace the system-board
Out of alternate disk storage for storage. Go to "Performing the checkout procedure"
on page 177.
Addressed device failed to respond to selection. Go to "Performing the checkout
procedure" on page 177.
Disk returned wrong response to adapter. Go to "Performing the checkout procedure"
on page 177.
Storage subsystem configuration error. Go to "Performing the checkout procedure" on
page 177.
Controller detected device bus interface error. Go to "Performing the checkout
procedure" on page 177.
Controller timed out a device command. Go to "Performing the checkout procedure"
on page 177.
Device bus interface error. Go to "Performing the checkout procedure" on page 177.
Configuration error, incorrect connection between cascaded enclosures. Go to
"Performing the checkout procedure" on page 177.
Configuration error, connections exceed IOA design limits. Go to "Performing the
checkout procedure" on page 177.
Configuration error, incorrect multipath connection. Go to "Performing the checkout
procedure" on page 177.
Configuration error, incomplete multipath connection between controller and enclosure
detected. Go to "Performing the checkout procedure" on page 177.
Configuration error, incomplete multipath connection between enclosure and device
detected. Go to "Performing the checkout procedure" on page 177.
Attached enclosure does not support required multipath function. Go to "Performing
the checkout procedure" on page 177.
Multipath redundancy level got worse. Go to "Performing the checkout procedure" on
page 177.
Device bus fabric error. Go to "Performing the checkout procedure" on page 177.
Temporary device bus fabric error. Go to "Performing the checkout procedure" on page
177.
Unsupported enclosure function detected. Go to "Performing the checkout procedure"
on page 177.
PCI bus error detected by controller. Go to "Performing the checkout procedure" on
page 177.
PCI bus error detected by controller. Go to "Performing the checkout procedure" on
page 177.
Temporary disk data error. Go to "Performing the checkout procedure" on page 177.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps704

Table of Contents