IBM PS703 Service Manual page 63

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 17. B7xxyyy Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
0104
0105
0106
0107
0200
0201
0202
0302
0441
0443
0601
Description
System firmware failure. Machine check,
undefined error occurred.
System firmware detected an error.
More than one request to terminate the
system was issued.
System firmware failure.
System firmware failure. The system
detected an unrecoverable machine
check condition.
System firmware has experienced a low
storage condition
System firmware detected an error.
Informational system log entry only.
System firmware failure
Service processor failure. The platform
encountered an error early in the
startup or termination process.
Service processor failure.
Informational system log entry only.
Action
1. Check for server firmware updates.
2. Update the firmware.
Go to "Isolating firmware problems" on page
216.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 216.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 216.
No immediate action is necessary.
Continue running the system normally. At the
earliest convenient time or service window,
work with IBM Support to collect a platform
dump and restart the system; then, go to
"Isolating firmware problems" on page 216.
No immediate action is necessary.
Continue running the system normally. At the
earliest convenient time or service window,
work with IBM Support to collect a platform
dump and restart the system; then, go to
"Isolating firmware problems" on page 216.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 216.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
No corrective action is required.
Note: This code and associated data can be
used to determine why the time of day for a
partition was lost.
Chapter 2. Diagnostics
51