IBM PS703 Service Manual page 44

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 10. 1xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error
Description
Codes
3134
Fault on the hardware
monitoring chip
8400
Invalid configuration decode
8402
Unable to get VPD from the
concentrator
8413
Invalid processor 1 VPD
32
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Action
Perform the DTRCARD symbolic CRU isolation procedure by
completing the following steps:
1. Reseat the PCIe expansion card.
2. If the problem persists, replace the expansion card.
3. If the problem persists, go to the "Checkout procedure" on page
176.
4. Perform one of the following:
a. If the location code reported with this SRC is Un-P2-C20,
replace the expansion system-board assembly, as described in
"Removing the expansion unit for a PS704 blade server" on
page 237.
b. If the location code reported with this SRC is Un-P1-C20,
replace the base system-board and chassis assembly, as
described in "Replacing the FRU system-board and chassis
assembly" on page 264.
The DTRCARD symbolic CRU isolation procedure is in "Service
processor problems" on page 193
1. Check for server firmware updates.
2. Apply any available updates.
3. If the problem persists:
a. Go to "Checkout procedure" on page 176.
b. Replace the system-board, as described in "Replacing the FRU
system-board and chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the base system-board (Un-P1) and chassis assembly, as
described in "Replacing the FRU system-board and chassis
assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Perform one of the following:
a. If the location code reported with this SRC is Un-P2, replace
the expansion system-board assembly, as described in
"Removing the expansion unit for a PS704 blade server" on
page 237.
b. If the location code reported with this SRC is Un-P1, replace
the base system-board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on
page 264.