IBM PS703 Service Manual page 108

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA340020
BA340021
BA400001
BA400002
96
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description
A logical partition event communication
failure occurred when writing the
BladeCenter open fabric manager
parameter data to the service processor.
A logical partition event communication
failure occurred when writing the
BladeCenter open fabric manager system
initiator capabilities data to the service
processor.
Informational message: DMA trace
buffer full.
Informational message: DMA map-out
size mismatch.
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.