5.4 Option 2, code SF1/SU2

On the stator housing, there are two 7 pin male device
connectors (Binder 723) and in the case of the speed module option, there is
also an 8 pin male device connector, assigned in accordance with the selected
option.
The supply voltage and the calibration signal of plugs 1 and 3 are
direct coupled via multifuses (automatically resetting fuses).
Assignment for plug 1:
Voltage supply and frequency output signal.
Connec
Binder 723
6
1
5
7
2
3
4
Top view
1)
Factory default; complementary signals RS 422
CAUTION
The torque flanges of option 3, code SF1/SU2 are only intended for
operation with a DC supply voltage. They must not be connected to older
HBM measuring amplifiers with square wave excitation. This could lead
to the destruction of the connection board resistances, or other errors in
the measuring amplifiers (the torque flange, on the other hand, is
protected and once the proper connections have been re established, is
ready for operation again).
HBM
Pin assignment
tor
Binder
pin
1
Torque measurement signal (frequency
output; 5V
2
Supply voltage 0 V;
3
Supply voltage 18 V ... 30 V
4
Torque measurement signal (frequency
output; 5 V
5
Measurement signal 0 V; symmetrical
6
Calibration signal trigger 5 V − 30 V
7
Calibration signal 0 V;
Shielding connected to enclosure ground
1)
; /0 V)
1)
/12 V)
T10FS
Wire
Sub D
color
connec
tor
pin
wh
13
bk
5
bu
6
rd
12
gy
8
gn
14
gy
8
A0785 14.0 en