Circular Run Out Values - HBM T10FS Mounting Instructions

Torque flange
Hide thumbs Also See for T10FS:
Table of Contents

Advertisement

74

13.2 Circular run out values

circular run−out−axial AB
circular run−out−radial AB
Internal centering
Hardness 46 ... 54 HRC
0,8
Surface quality of the run out and
concentric surfaces (A, B and AB)
Measuring range
100 N⋅m
200 N⋅m
500 N⋅m
1 kN⋅m
2 kN⋅m
3 kN⋅m
5 kN⋅m
10 kN⋅m
To ensure that the torque flange retains its characteristics once it is installed,
we recommend that the customer also chooses the specified form and position
tolerances, surface quality and hardness for the connections provided.
HBM
circular run out−axial tolerance
(mm)
0.01
0.01
0.01
0.01
0.02
0.02
0.02
0.02
B
A
circular run−out−radial
tolerance (mm)
0.01
0.01
0.01
0.01
0.02
0.02
0.02
0.02
A0785 14.0 en