Barco DP2K SLP Series Service Manual page 400

Hide thumbs Also See for DP2K SLP Series:
Table of Contents

Advertisement

Index
20670 367
20671 367
21113 368
21117 368
21121 368
21125 368
21129 368
21133 368
21137 368
21141 368
21210 369
21220 369
21221 369
21222 370
21223 370
21224 370
21225 370
21226 370
21227 370
21228 370
21244 370
21245 371
21246 371
21247 371
21248 371
21249 371
21250 371
21251 371
21252 371
21268 371
21269 372
21272 372
21282 372
21283 372
21284 372
21309 372
21310 373
21311 373
21312 373
21313 373
21314 373
21315 373
21316 373
21335 373
21342 374
21345 374
21348 374
21349 374
21352 374
21353 375
21356 375
21357 375
21360 375
21361 375
21362 375
21365 375
21366 375
21371 376
21372 376
21373 377
21376 377
21380 377
21384 377
error code name
400
R5906848 /04
DP2K SLP Series
LCB – ldm initialization failed (safety switch
open) 369
ldm 1 – 15vm voltage too high 354
ldm 1 – 15vm voltage too low 354
ldm 1 – 380vm pfc voltage too high 372
ldm 1 – 380vm pfc voltage too low 371
ldm 1 – 380vm voltage too high 354
ldm 1 – 380vm voltage too low 354
ldm 1 – 380vma voltage too high 354
ldm 1 – 380vma voltage too low 354
ldm 1 – heatsink pfc temperature sensor
open 355
ldm 1 – heatsink pfc temperature sensor
short 355
ldm 1 – heatsink pfc temperature too high 355
ldm 1 – mains voltage too low 355
ldm 1-2 – heatsink rectifier temperature sensor
open 362
ldm 1-2 – heatsink rectifier temperature sensor
short 361
ldm 1-2 – heatsink rectifier temperature too
high 361
ldm 1-6 – not configured (no
communication) 363
ldm 1-7 – not configured (no
communication) 364
ldm 1-7 – not configured (not initialized) 372
lls – too many laser banks are off 372
lpt 1 - lls bank 9 hot side temperature too
high 374
lpt 1 - temperature cold side bank 9 high. 373
Error code name
++12v - voltage high 342
++12v - voltage low 342
+24v - voltage high 340
+24v - voltage low 341
+24v - voltage too low 340
5043 298
ambient - temperature high 314
ambient - temperature sensor open 314
ambient - temperature sensor short 315
ambient - temperature too high 314
anode fan - speed low 300
anode fan - speed too low 299
cathode fan - speed low 301
cathode fan - speed too low 300
cold mirror fan - speed too low 297
dmd - temperature hardware protection
warning 340
dmd blue - temperature high 315
dmd blue - temperature low 316
dmd blue - temperature sensor open 316
dmd blue - temperature sensor short 317
dmd blue - temperature too high 315
dmd green - temperature high 317
dmd green - temperature low 318
dmd green - temperature sensor open 318
dmd green - temperature sensor short 319
dmd green - temperature too high 317
dmd red - temperature high 321
dmd red - temperature low 321
dmd red - temperature sensor open 322
dmd red - temperature sensor short 322

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp2k-10slpDp2k-8slp

Table of Contents