Troubleshooting
Code 20577: "LDM 1-3 – Heatsink rectifier temperature too high"
For this error the same troubleshooting table can be applied to as for code 20377: "LDM 1-2 – Heatsink
rectifier temperature too high".
Code 20578: "LDM 1-3 – Heatsink rectifier temperature sensor shorted"
For this error the same troubleshooting table can be applied to as for code 20378: "LDM 1-2 – Heatsink
rectifier temperature sensor shorted".
Code 20579: "LDM 1-3 – Heatsink rectifier temperature sensor open"
For this error the same troubleshooting table can be applied to as for code 20379: "LDM 1-2 – Heatsink
rectifier temperature sensor open".
Code 20583: "LDM 1-3 – Heatsink drain temperature too high"
For this error the same troubleshooting table can be applied to as for code 20377: "LDM 1-2 – Heatsink
rectifier temperature too high".
Code 20584: "LDM 1-3 – Heatsink drain temperature sensor shorted"
For this error the same troubleshooting table can be applied to as for code 20378: "LDM 1-2 – Heatsink
rectifier temperature sensor shorted".
Code 20585: "LDM 1-3 – Heatsink drain temperature sensor open"
For this error the same troubleshooting table can be applied to as for code 20379: "LDM 1-2 – Heatsink
rectifier temperature sensor open".
Code 20609: "LDM 1-4 – LLS bank 7 drain voltage too high"
For this error the same troubleshooting table can be applied to as for code 20323: "LDM 1-2 – LLS bank 1
drain voltage too high".
Code 20613: "LDM 1-4 – LLS bank 8 drain voltage too high"
For this error the same troubleshooting table can be applied to as for code 20323: "LDM 1-2 – LLS bank 1
drain voltage too high".
Code 20621: "LDM 1-4 – LLS bank 7 current too high"
For this error the same troubleshooting table can be applied to as for code 20335: "LDM 1-2 – LLS bank 1
current too high".
Code 20625: "LDM 1-4 – LLS bank 8 current too high"
For this error the same troubleshooting table can be applied to as for code 20335: "LDM 1-2 – LLS bank 1
current too high".
Code 20645: "LDM 1-4 – LLS bank 7 temperature too high"
For this error the same troubleshooting table can be applied to as for code 20359: "LDM 1-2 – LLS bank 1
temperature too high".
Code 20646: "LDM 1-4 – LLS bank 7 temperature sensor shorted"
For this error the same troubleshooting table can be applied to as for code 20360: "LDM 1-2 – LLS bank 1
temperature sensor shorted".
Code 20647: "LDM 1-4 – LLS bank 7 temperature sensor open"
For this error the same troubleshooting table can be applied to as for code 20361: "LDM 1-2 – LLS bank 1
temperature sensor open".
366
R5906848 /04
DP2K SLP Series