Code 5835: "ti-link-decryptor - security log is almost full"
Situation
The security log is almost full
indicates that there are less
than 512 log entry locations
available in the Link Decryptor
log before the log is full.
The attached server needs to
read the log which will clear
the log of the projector.
Code 5836: "ti-link-decryptor - security log is full"
Situation
The Security Log Error
indicates that there is no more
room to write log entries in the
Link Decryptor log file.
Code 5837: "ti-link-decryptor - read system status failed "
Situation
Link Decryptor is not correctly
seated.
Code 5850: "imb - no communication"
Situation
Exceptional software failure.
No communication with media
block
Solution
When this warning is active, the DCI compliant server needs to extract the
log data (via ASM/TLS session) from the Link Decryptor Security Log. This
can take some time. Reads of the security log by any other entity/means
will not impact this warning.
Solution
When this error is active, the DCI compliant Server needs to extract the log
data (via ASM/TLS session) from the link decryptor Security Log. Reads of
the security log by any other entity/means will not impact this error. This
error will remain active until the Server reads enough log entries to create
room for 512 log entries. This can take some time. Playback will be
prohibited (black image) as long as this error is active.
Solution
Reseat the Link Decryptor. See service manual chapter "Replacement of
the Link Decryptor", page 217.
If problem remains, replace Link Decryptor.
Solution
Reboot the projector.
Check if the media block is well seated.