Barco DP2K SLP Series Service Manual page 380

Hide thumbs Also See for DP2K SLP Series:
Table of Contents

Advertisement

Troubleshooting
→ Command messages also indicate originator.
Apr 6 14:09:07 localhost local0.info dp60[233]: system - load fcb file "lamp-on"
→ on fan controller board, lamp-on state is set.
External commands received by the Barco controller are preceded with the command (port = xxx)
string
Where xxx can be :
/dev/ttyS0:0 = Command comes from the serial connection labeled ("RS232 IN"). That can be from a
touch panel which is connected through a RS232 cable, or from a communicator which is connected
serially.
/dev/ttyS2:0 = Command comes from a touch panel attached with a dedicated cable to the back of the
projector (touch panel input).
/dev/ttyS3:0 = Command comes from the TI board. This is typically a command that is part of a macro
stored on that board.
10.36.62.17:43680 = Command comes from a remote machine with indicated IP address, followed by
the local of the remote machine that send this command internal. The command is initiated internally, due
to an internal reason.
button = button is triggered from the keypad, attached to the projector.
Some examples :
command (port = /dev/ttyS2:0) - set network ip-address to 10.140.162.141 (dhcp off) =
From the touch panel, the IP address of the projector was set to 10.140.162.141
command (port = 10.36.62.17:43680) - set network ip-address to 10.36.62.62 (dhcp
off) = From a device with IP address 10.36.63.17, the IP address of the projector was changed to
10.36.63.17
command (port = /dev/ttyS0:0) - set dowser open. = From a touch panel or PC, connected
serially (connector labeled "Touch panel"), the dowser was set to open.
command (port = /dev/ttyS0:0) - set lamp off = From a touch panel or PC, connected serially
(connector labeled "Touch panel"), the lamp was powered off.
command (port = internal) - set lamp off = For an internal reason the state of the lamp was set to
off.
command (port = button) - set dowser closed = The dowser was closed from the keypad.
The error messages are explained in the troubleshooting list - code 5831
ICP log files
Example of log file content :
2010/04/06 09:02:40.964797 I
2010/04/06 09:02:40.980964 I
2010/04/06 09:02:41.039022 I
2010/04/06 09:02:41.049829 I
2010/04/06 09:02:41.051245 I
2010/04/06 09:02:41.051755 I
2010/04/06 09:02:41.052149 I
2010/04/06 09:02:41.052897 I
2010/04/06 09:02:43.632304 I
2010/04/06 09:02:43.633017 D
2010/04/06 09:02:43.633476 D
2010/04/06 09:02:43.792939 D
...
Format
'Date Time' 'Severity' 'message'
Where :
'Date Time' = the time when the event occurred.
'Severity' = One character severity indication can be : 'D" (Debug) – "E" (Error) – "I" (Informational) -
"U" (User).
'message' = The actual error message.
Example :
380
R5906848 /04
DP2K SLP Series
ICP application 1.2(126) init
successfully initialized the LoginLevelProtection mutex
Autotiming initialized
Autotiming using VSyncs
Started Autotiming Port threads
Autotiming started
Port thread running
Port thread running
Started Autotiming Main thread
Autotiming thread running
Autotiming: blank the image
Autotiming: unblank the image
Shows the ICP package