Power Specifications - CUMMINS ALLISON JetScan iFX i100 Operating Instructions Manual

Hide thumbs Also See for JetScan iFX i100:
Table of Contents

Advertisement

Power Specifications

High-voltage levels may be present. Risk of electric shock.
Turn power OFF and unplug power cord from machine before cleaning.
Do not attempt repairs. Repairs must be made by authorized Cummins Allison
personnel.
Plug three-prong grounded plug (supplied) into properly grounded three-prong
outlet.
Read and understand all instructions before use.
Only use Cummins Allison supplied power adapter.
Use of any other power adapter may damage equipment.
Power Requirements
• Input voltage: AC input 100 - 240 VAC
• Frequency: 50/60 Hz
• Full load amps (FLA): 4A
• Power-adapter-output rating: 19V DC, 9.47A (UL, ITE listed, Class 2 power supply)
• Electrical-supply circuit: The customer must provide a single-phase, dedicated power line that
meets the machine's power requirements. Use a properly grounded circuit breaker in compliance
with applicable local electrical code.
Power disruptions and fluctuations causing input voltage other than listed in power requirements
can lead to improper operation of this device, damage to electrical components, and failure. Such
occurrences are not covered under the machine warranty or preventative maintenance agreement
for this device. Power conditioning/stabilizing devices are available for purchase from Cummins
Allison.
Improper voltage levels can cause equipment malfunction, damage
electrical components, and void warranty.
Provide separate circuit serving only this device to ensure proper
operation.
Follow listed power requirements to ensure proper operation.
Provide power conditioning/stabilizing devices if necessary.

Hide quick links: