8

Thickness Adjustment Dial

The dial located on the top of the machine adjusts the tightness of the feeder through which
documents pass during operation. The dial has positive and negative adjustment numbers, with 0
at the center of the adjustment range.
For normal feeding, start with 0 at the top of the dial.
To help reduce the occurrence of doubles or chains, turn the dial to the right, so a
negative number is at the top, decreasing the distance between the rollers.
Turning the dial to the left, so a positive number is at the top, increases the
spacing between the rollers, allowing documents to pass through more easily.

Interior Upper-Transport Plate Diagrams

*
The interior upper-transport plate must be raised for jam recovery and daily cleaning. The upper-
transport plate is accessed by lifting the display panel, and it is disengaged by pressing down on
the release levers. After disengaging, lift the upper-transport plate to the open, locked position, as
shown above. To close the upper-transport plate, press down on the release levers to unlock it
from the open position. Next, push down on the upper-transport plate until it locks in the closed
position, which produces an audible click.
Upper-transport plate closed
(Operating position)
*
Release levers (highlighted in white)
JetScan iFX
Upper-transport plate open
*
*
®
i100 Scanner