How to Use the Verify Function

The verify function runs documents "off-line" without adding them to machine totals and is
intended for use in recounting and reconciling any count suspected of being incorrect.
The verify function provides a unique day total that only tracks documents processed while using
this function. Verification counts are not added to current batch, sub-batch or day totals and are
not sent to host systems that may be connected to the machine.
When imaging options are activated (serial-number, check or ticket capture),
image data is not captured while using the verify function.
The verify function can be used with current mode settings or a customized environment.
Customized settings – such as disabling counterfeit detection or lowering density settings – only
apply to the active verify session and are not retained for future sessions.
When users exit the verify function, the machine resumes its previous operating mode, totals
and settings.
To use the verify function:
1.
Press VERIFY. The VERIFY key is yellow and the total changes to 0.
2.
If desired, change sensitivity settings, and then process the documents.
These changes are only active while using the verify function and do not
affect operating-mode settings.
3.
Press VERIFY again to resume normal operation.
© 2013 Cummins-Allison Corp.