Setup Main Menu 1 Key
AUDIO ALARM
Pressing SET prompts the ALARM ENABLE SELECTION MENU below.
The audio alarm can be turned ON or OFF for these stopping conditions:
• STRNGR (stranger detect)
• CF (suspect document)
• DOUBLE (double)
• JAM (jam)
• LIMIT (strap limit)
• CHAIN (chain)
The SNC key appears when the serial-number
capture option is active.
The alarm sounds three beeps for a jam, double, chain or spacing error,
and one beep for all other conditions.
When KEYS is ON, a tone sounds when keys are touched on the screen.
When configuration is complete, press EXIT to return to SETUP MAIN
MENU 1.
© 2013 Cummins-Allison Corp.
Description
• NOCALL (no call)
• SPACE (spacing error)
• DC (denomination change)
• SNC (serial-number capture error)
• STKERR (stacking-sensor error)