4.5 Wiring Connections

4.5.1 Wiring schematics
Note:
R See 4.5.4 Distribution box switch settings (page 37, 38, and 40) for information about distribution box switch
settings (3 types of switches: DIP switches, terminate switch, and repeat switch).
R See page 42 for information about lift controller DIP switch settings.
R Insert the wires fully into the connection terminals. After inserting the wires, pull slightly on each wire to make sure
it is firmly connected.
Basic system example
Lobby Station (1)
OFF
ON
V700/V703 K-IN K-OUT
DC IN
L1 L2 C1C2 S1 S2
NP
NP
NP
Access
12 V DC
controller
(input)
POWER SUPPLY UNIT
Electric
(output)
NP: Non-polarised
R The required distribution switch settings for the basic system example are as follows.
– DIP switch: only set the number 1 switch to the "on" position
– Terminate switch: set to the "on" position
– Repeat switch: set to the "off" position
Control Box (1)
V900/
V901/
NP
V703
Power
supply
DC IN
POWER SUPPLY UNIT
lock
Distribution Box (1)
NP
NP
DIP SW : 1=ON
NP
POWER SUPPLY UNIT
REPEATER SW
TERMINATION SW : ON
4. Installation
Room unit (up to 20)
Main Monitor Door Station
NP
1
NP
DC IN
NP
: OFF
D1
1
D2
2
D3
3
D4
4
R1
5
R2
6
R3
7
IN1
8
IN2
9
IN3
10
NP
IN4
11
P1
12
P2
13
D1
1
D2
2
D3
3
D4
4
R1
5
R2
6
R3
7
IN1
8
IN2
9
IN3
10
NP
IN4
11
P1
12
P2
13