Wiring Connections - Panasonic VL-VM701 Installation And Operating Instructions Manual

Vl-vm series. video intercom system - loby station/distributor
Table of Contents

Advertisement

4. Installation

4.6 Wiring Connections

4.6.1 Wiring schematics
Note:
R See page 23 for information about connections for power supply units.
R See page 40 for information about lobby station DIP switch settings.
R See page 41 for information about distributor DIP switches when using bus wiring.
R Insert the wires fully into the connection terminals. After inserting the wires, pull slightly on each wire to make sure
it is firmly connected.
Star wiring example
Maximum number of devices
R Lobby station: up to 1
R Main monitor: up to 32 (depending on the composition of the lobby station's modules)
Important:
R When using star wiring, do not connect wires from main monitors to L1 and L2.
R Wiring is non-polarised.
12 V
AC / DC
Power
Electric
supply
lock
(output)
Open door
sensor (input)
#2
D1
1
D2
2
IN1
1
IN2
2
OUT1
1
OUT2
2
#4
D1
1
2
D2
IN1
1
IN2
2
OUT1
1
OUT2
2
36
DIP SW
K-OUT
K-IN1/K-IN2
NO COM NC
C1
#6
#8
#10
#12
#14
#16
DC IN
C2C1C2 L1 L2
Lobby station
24 V DC
POWER
SUPPLY
UNIT
Access
controller (input)
#1
D1
#5
D2
IN1
IN2
OUT1
#7
OUT2
#9
#3
#11
D1
D2
IN1
IN2
#13
OUT1
OUT2
Main monitor
#15
To AC power
outlet
1
2
1
2
1
2
1
2
1
2
1
2

Hide quick links: