5.2.13 List of PC programming parameters
The following parameters are available when using PC programming.
Control Box — Room settings
Parameter
Room No.
Floor No.
Lift access permission (Lift 1–3)
Control Box — General settings
Parameter
Monitor Time Out
Talk Time Out
Camera Signal
Lift Signal Mode
Lift Signal Time
Visitor Call Mode
Terminal 1–4 Extension Number
*1
Description and available settings
Determines the room number of the main monitor
connected to the corresponding control box port,
distribution box number, and distribution box port.
(1–99999; 0 is displayed when the room is not
configured)
Determines the floor number setting of the
corresponding room number.
(0–99; 0 is the ground floor)
Determines which lifts can be used by visitors to each
lobby station.
Description and available settings
Determines the amount of time that passes when
watching camera images before the standby screen is
displayed.
[0]: 180 SEC
[1]: 90 SEC
[2]: 60 SEC
[3]: 30 SEC
Determines the amount of time that passes when
talking before the standby screen is displayed.
[0]: 90 SEC
[1]: 60 SEC
[2]: 30 SEC
[3]: 180 SEC
[4]: 300 SEC
Tells the system what signal format is used by the
external camera.
[0]: PAL
[1]: NTSC
Determines the signalling method used by the lift
controller to communicate with the lift. Select the signal
type according to the specifications of the lift.
[0]: RELAY
[1]: BINARY
After a visitor is admitted, this setting determines the
amount of time that the visitor can use the lift to visit the
corresponding floor.
If the lift has a similar setting, set this parameter to any
value other than "0"; the lift setting will take priority.
(1–900 SEC, or 0 to disable)
Determines if visitors can call rooms directly or if their
calls are directed to a reception terminal.
[0]: ROOM MODE
[1]: RECEPTION MODE
Tells the system the extension number for terminal 1–
4. (24 digits max.)
5. Programming
Default
0
0
(No lifts can be
used)
Default
0
(180 SEC)
0
(90 SEC)
0
(PAL)
0
(RELAY)
300
(300 SEC)
0
(ROOM MODE)
53